Groupe : aralab

Extraits du catalogue

TESTING TESTA TT TESTA CT TEMPERATURE TESTING CLIMATIC TESTING ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBER
Ouvrir le catalogue en page 1
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the Environment. Your Own Climate. TESTA temperature and humidity testing chambers offer...
Ouvrir le catalogue en page 2
- - ...«ininML’ r-iBBPB üilp ■ Slnï tëf ■■■■BiMf ■ SSS£r ï®*1 '■IIOlllllH'.llj, Il ■SEW àw '■liraihiHFiifr !■■ ■ ■■■■■}[iiul IIiriiIIi.ir-.n iiît ■ ■■■■"'» ■■■■■■■■■ liliHE l'irais ■■■■■■■■■■■ aiBi , ;iiiiii^aijl|
Ouvrir le catalogue en page 3
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 10 TESTA CHAMBERS - MODELS AND REFERENCES • • • • TESTA TT CHAMBERS - TEMPERATURE ONLY TESTA TT CHAMBERS • • • • TESTA CT CHAMBERS - TEMPERATURE AND HUMIDITY TESTA CT CHAMBERS EC - models with Capacitive humidity sensor EP - models with Psychrometric humidity sensor ECP - models with both Capacitive and Psychrometric humidity sensors. Please consult Aralab if in doubt about the type of sensor to chose RANGES FOR CLIMATIC AND TEMPERATURE TESTING • • • • TESTA CT TESTING CHAMBERS Performance in CLIMATIC testing range | only TESTA CT chambers...
Ouvrir le catalogue en page 4
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS • • • • SYSTEM STRUCTURE 6. Observation Window (optional) 8. Touch screen controller aralab ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBERS
Ouvrir le catalogue en page 5
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 300 - PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 300 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2403 1865 1840 According to castor wheel levelling 1. Standard refrigeration system is air cooled Supply power TESTA 300 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 30mA differential 50mm water drain at floor level 3. Water cooled option (is included as standard in -75ºC models) Supply...
Ouvrir le catalogue en page 6
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS Wj TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Température range in Space @ low temp. point ± 0,2 ± 0,2 in Space @ high temp point Temperature fluctuation in time Temperature change rate (2a) Qb) PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Water Optional Standard Performances...
Ouvrir le catalogue en page 7
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 500 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 500 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2456 1470 1450 According to castor wheel leveling 1990 1960 According to castor wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 500 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential 50mm water drain at floor level 3. Electrical cabinet...
Ouvrir le catalogue en page 8
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Température range in Space @ low temp. point °C in Space @ high temp point °C Temperature fluctuation in time °C Temperature change rate Qa) (2b) cooling K/min heating K/min PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Performances...
Ouvrir le catalogue en page 9
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 1.000 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 1.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2755 1350 1330 According to caster wheel leveling 2060 2030 According to caster wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 1000 TT/CT 75 and 10K model: 2. Services hub installation needs: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 63A + N with 300mA...
Ouvrir le catalogue en page 10
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range Max °C 180 180 180 180 180 180 Temperature uniformity(1 in Space @ low temp. point in Space @ high temp point ± 1,4 Temperature fluctuation in time ± 0,1°C to ± 0,3°C PERFORMANCE IN HUMIDITY TESTING Humidity range in space Fluctuation in time Test space volume Shelves number of shelves included (more can be added) maximum weight load per shelf kg Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Nominal...
Ouvrir le catalogue en page 11
TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 0 1. Standard réfrigération system is air cooled2. Services hub installation needs: 0 %” demineralized water supply Condutivity: <50pS/cm , TDS <35PPM 0 50mm water drain at floor level 3. • Electrical cabinet installation needs:Supply power TESTA 1500 TT/CT 50: 400VAC, 50Hz, 32A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential Supply power TESTA 1500 TT/CT 75: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential # RJ45...