CNAP® Monitor ENGLISH
1 /4Pages

CNAP® Monitor ENGLISH

CNAP® Monitor ENGLISH
1 /4Pages

Extraits du catalogue

CNAP® Monitor ENGLISH-1

CONTINUOUS NON-INVASIVE BLOOD PRESSURE & HEMODYNAMICS EASY AND SAFE HEMODYNAMIC MONITORING

 Ouvrir le catalogue en page 1
CNAP® Monitor ENGLISH-2

...every beat counts CONTINUOUS NON-INVASIVE HEMODYNAMIC CONTROL FULL HEMODYNAMIC PICTURE Hemodynamics Continuous non-invasive blood pressure waveform / trendview Cardiac Output CO, CI, SV, SI Vascular Resistance SVR, SVRI Dynamic Fluid Management PPV, SVV Continuous Blood Pressure: Sys, Dia, MAP, Pulse and Upper arm NBP: Sys, Dia CONVENIENT CNAP® FINGER SENSOR NON-INVASIVE EASY-TO-USE AND QUICK Quick set-up and error-free application Blood pressure waveform and values immediately available Comparable with invasive clinical standards1-11, 21 Reliable tracking (e.g. in patients with volatile...

 Ouvrir le catalogue en page 2
CNAP® Monitor ENGLISH-3

...easy and safe hemodynamic monitoring EASY-TO-USE QUICK START UP COST EFFECTIVE PROVEN ACCURACY IN CLINICAL SETTINGS FAST & ACCURATE HEMODYNAMIC OVERVIEW 16,17 > CNAP® measurements are comparable to invasive arterial line measurements in terms of continuity, accuracy and waveform dynamics.1,2,3 > Early recognition15 > Fast intervention > Detection of hemodynamic reactions > ...without arterial catheter > CNAP® delivers reliable results for the efficient treatment of ICU and ER patients.4,5, 6,7 > CNAP® provides immediate hemodynamic status and detects blood pressure drops during the...

 Ouvrir le catalogue en page 3
CNAP® Monitor ENGLISH-4

TECHNICAL SPECIFICATIONS NBP – OSCILLOMETRIC BLOOD PRESSURE Measuring range Sys: Adult 40 - 260 mmHg, Pediatric 40 - 230 mmHg Dia: Adult 20 - 200 mmHg, Pediatric 20 - 160 mmHg Degree of protection BF (defibrillation proof) CI SI SVRI sealed lead-gel, operating time: 2 hours (fully charged battery) Supply frequency ~50/60 Hz PHYSICAL Weight 7,5 kg (16,6 lbs) including accessories and cables Height 280 x 270 x 250 mm (11 x 10,6 x 9,8 inch) ENVIRONMENTAL Temperature operation: 10°C - 40°C (50°F - 104°F) storage: 0°C - 40°C (32°F - 104°F) Humidity operation: 15% - 85% non condensing storage:...

 Ouvrir le catalogue en page 4

Tous les catalogues et fiches techniques (PDF) CNSystems Medizintechnik

* Les prix s'entendent hors taxe, hors frais de livraison, hors droits de douane, et ne comprennent pas l'ensemble des coûts supplémentaires liés aux options d'installation ou de mise en service. Les prix sont donnés à titre indicatif et peuvent évoluer en fonction des pays, des cours des matières premières et des taux de change.