Proximal Femoral (Hook) Plate
24Pages

{{requestButtons}}

Extraits du catalogue

Proximal Femoral (Hook) Plate - 1

LCP Proximal Femoral Hook Plate Plating System. Technique Guide

Ouvrir le catalogue en page 1
Proximal Femoral (Hook) Plate - 3

Introduction Features and Benefits 2 Product Information Plates 17 O Image intensifier control This description is not sufficient for immediate application of the instrumentation. Instruction by a surgeon experienced in handling this instrumentation is highly recommended.

Ouvrir le catalogue en page 3
Proximal Femoral (Hook) Plate - 4

Features and Benefits The Synthes LCP Proximal Femoral Hook Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. LCP Periarticular Plating System The LCP Periarticular Plating System is capable of addressing: – complex fractures of the distal femur with the LCP Condylar Plate 4.5/5.0. – complex fractures of the proximal femur with the LCP Proximal Femoral Plate 4.5/5.0 or the LCP Proximal Femoral Hook Plate 4.5/5.0. – complex fractures of the proximal tibia with the LCP Proximal Tibial Plate 4.5/5.0 or the...

Ouvrir le catalogue en page 4
Proximal Femoral (Hook) Plate - 5

LCP Proximal Femoral Hook Plate System The LCP Proximal Femoral Hook Plate System has many similarities to traditional plate fixation methods, with a few important improvements. The technical innovation of locking screws provides the ability to create a fixed-angle construct while using familiar AO plating techniques. Locking capability is important for a fixed-angle construct in osteopenic bone or multifragment fractures where screw purchase is compromised. These screws do not rely on plate-to-bone compression to resist patient load, but function similarly to multiple, small angled blade...

Ouvrir le catalogue en page 5
Proximal Femoral (Hook) Plate - 6

AO Principles In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1 Those principles as applied to the LCP Proximal Femoral Hook Plate 4.5/5.0 are: Anatomic reduction Proximal hooks and anatomic plate profile assist reduction of metaphysis to diaphysis and facilitate restoration of the neckshaft angle by proper screw placement. Stable fixation The combination of conventional and locking plate fixation offers optimum fixation irrespective of bone density. Preservation of blood supply A limited-contact design reduces plate-to-bone contact...

Ouvrir le catalogue en page 6
Proximal Femoral (Hook) Plate - 7

Indications The LCP Proximal Femoral Hook Plate 4.5/5.0 is intended for fractures of the femur including: – Fractures of the trochanteric region, trochanteric simple, cervicotrochanteric, trochanterodiaphyseal, multifragmentary pertrochanteric, intertrochanteric, intertrochanteric reversed or transverse or with additional fracture of the medial cortex – Fractures of the proximal end of the femur combined with ipsilateral shaft fractures – Metastatic fracture of the proximal femur – Osteotomies of the proximal femur – Also for use in fixation of osteopenic bone and fixation of nonunions or...

Ouvrir le catalogue en page 7
Proximal Femoral (Hook) Plate - 8

Surgical Technique Required sets LCP Proximal Femoral Hook Plate Set 4.5/5.0 (stainless steel) Periarticular LCP Plating System Instrument Set Cannulated Locking and Cannulated Conical Screw 0 5.0 LCP Large Fragment Instrument Set LCP Large Fragment Screw Set Complete the preoperative radiographic assessment and pre- pare the preoperative plan. AP and lateral radiographs of the entire femur are necessary for complete evaluation. Trac- tion radiographs and views of the contralateral femur are useful adjuncts in the planning process. When considering use of the LCP Proximal Femoral Hook Plate...

Ouvrir le catalogue en page 8
Proximal Femoral (Hook) Plate - 9

Reduce fracture Reduce the fracture using a fracture table, clamps, Schanz screws, or other conventional reduction techniques. Alterna- tively, provisional indirect fracture reduction may be facili- tated by attaching the LCP Proximal Femoral Hook Plate 4.5/5.0 to the proximal segment with appropriately oriented screws, and then to the diaphysis with plate holding forceps Important: The fracture has to be meticulously reduced in order to avoid implant failure.

Ouvrir le catalogue en page 9
Proximal Femoral (Hook) Plate - 10

Surgical Technique Insert guide wires 310.243 Guide Wire 0 2.5 mm, with drill tip, length 200 mm. Stainless Steel Wire Guide 5.0, for Guide Wire 0 2.5 mm Wire Guide 7.3, for Guide Wire 0 2.5 mm Before placing the plate on the bone, thread the wire guides into the plate holes for each of the proximal locking screws. Use the wire guide 7.3 in the proximal screw hole, and a wire guide 5.0 in the second locking screw hole. The wire guides can also be used as a manipulation aid for positioning the plate on the proximal femur. Seat hooks using a 4.5 mm cortex screw aimed toward the lesser...

Ouvrir le catalogue en page 10
Proximal Femoral (Hook) Plate - 11

Using fluoroscopic image control (AP and lateral), insert a guide wire л 2.5 mm through the wire guide in each of the proximal locking holes. Guide wires should reach, but not penetrate, subchondral bone. 50° – Placement of the proximal guide wire in the AP view is into the midportion of the inferomedial quadrant of the femoral head along a path subtending a 50° angle relative to the calcar femoralis. Guide wire placement in this manner will facilitate placement of the proximal locking screw at a 95° angle to the femoral shaft. – The proximal guide wire is ideally placed central in the...

Ouvrir le catalogue en page 11
Proximal Femoral (Hook) Plate - 12

Surgical Technique Insert proximal 7.3 mm cannulated screw 314.050 Screwdriver, hexagonal, cannulated 314.230 Screwdriver Shaft, hexagonal, cannulated 338.490 Quick Coupling for Small Air Drill Compact Air Drive and Power Drive For predrilling in dense bone Use the measuring device over the guide wire to measure for screw length. Select the appropriate length 7.3 mm cannulated locking screw. Use the cannulated hexagonal screwdriver to remove the wire guide. Technique Tip: The self-drilling, self-tapping flutes of the 7.3 mm and 5.0 mm screws make predrilling and pretapping unnecessary in...

Ouvrir le catalogue en page 12
Proximal Femoral (Hook) Plate - 13

Insert the locking screw using fluoroscopy with power equipment and the 4 Nm torque limiting attachment. However, final seating and tightening must be done manually. Once the screw has been locked to the plate, the guide wire may be removed. Note: In cases where it is necessary to pull the plate to the bone, use a fully threaded 7.3 mm cannulated conical screw in the proximal screw hole. However, use caution to avoid changing the alignment of the guide wire with the conical screw. If misalignment occurs, it may preclude final exchange of the conical screw for a locking screw, and thereby...

Ouvrir le catalogue en page 13

Tous les catalogues et fiches techniques (PDF) Depuy Synthes

Catalogues archivés

  1. Concorde

    28 Pages

  2. CONDUIT™

    15 Pages

  3. DePuy Synthes

    81 Pages

  4. Anspach

    3 Pages

  5. Corail

    24 Pages

  6. Speed

    2 Pages

  7. attune

    80 Pages

  8. Polar

    4 Pages

  9. P F N A

    8 Pages

  10. DURALOC

    16 Pages

  11. MatrixNEURO

    8 Pages

  12. Anspach XMax

    4 Pages

  13. Colibri II

    4 Pages

  14. Spine

    25 Pages

  15. TomoFix

    60 Pages

  16. Sacral Bars

    16 Pages

  17. Pelvic C-Clamp

    20 Pages

  18. LCP

    24 Pages

  19. PFNA

    112 Pages

  20. VA-LCP Elbow

    48 Pages

  21. Distal Radius

    44 Pages

  22. Olecranon

    30 Pages

  23. LCP Hook Plate

    28 Pages

  24. LCP S-A

    4 Pages

  25. Epoca

    4 Pages

  26. Philos

    32 Pages

  27. MultiLoc

    68 Pages