IDCAM
32Pages

{{requestButtons}}

Extraits du catalogue

IDCAM - 1

IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 Morse taper Range / IDCA

Ouvrir le catalogue en page 1
IDCAM - 2

IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS Since 25 years, IDI firm (Implants Diffusion International), in collaboration DIFFUSION with a team of researchers, engineers and dental surgeons, has regularly INTERNATIONAL developped new products intended to implantology. Implants Diffusion International invests a great deal in the research of new technologies such as RBS drill, state of surface SMA +Tio2, IMPLANTS DIFFUSION Osteosinus… INTERNATIONAL “WE DEVELOP AND MANUFACTURE IN FRANCE” The IDI lines are developped and manufactured in the...

Ouvrir le catalogue en page 2
IDCAM - 3

THE QUALITY COMMITMENT OF THE IDI COMPANY / THE LIFETIME WARRANTY IDI - Implants Diffusion International - develops, manufactures and distributes the largest range of dental implants all over the world, as well as implantology and dental surgery equipment. IDI products are manufactured in France exclusively. They’re resulting from the essential work of the Research and Development Department. For IDI, to be close to practitioners, hospitals and implantology training centres is a great deal, because they take part to the constant innovation. The IDI teams, concerned with the trust...

Ouvrir le catalogue en page 3
IDCAM - 4

IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL Implant range and prosthetic systems 05 MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL ACCESSORIES & INSTRUMENTS

Ouvrir le catalogue en page 4
IDCAM - 5

MORSE TAPER CONNECTION “On a surgical aspect, IDCAM implants are easier and more pleasant to place comparing to other implants. Furthermore, with RBS drills, we can harvest a great quantity of bone. On a prosthetic aspect, at this time I just have used the kit C for unit implants, and I think that’s an excellent one” Dr Riad M. (Lebanon)

Ouvrir le catalogue en page 5
IDCAM - 6

WHY CHANGING FOR IDCAM ? There’s more than 1000 brands of dental implants all over the world. WHY IDCAM ? – For Technology and Innovation – For the IDCAM Concept – For the price COMPENDIUM OF SCIENCES APPROVED TECHNOLOGIES Its alloy - Two phases Ti6Al4V grade 5 Studies of Buser (2004), Zhao and Schwartz (2005), Carl E Misch. Its state of surface - Sandblasted and acid-etched and TiO2, Roughness of 1,76μ – Sandblasted and acid-etched, passivated. Studies of Becker and Coll, Albrektsson and Wennerberg, Wennerberg, Hanson and Norton 2005. Its shape - Cylindro-tapered. – he cylindrical shape of...

Ouvrir le catalogue en page 6
IDCAM - 7

MORSE TAPER CONNECTION Concave The concave area allows to sustain grafted biomaterials during sinus lift. Safety The atraumatic round-shaped end limits the risks of damaging neighbouring tissues. Osseointegration The peripheral wedge groove increases the apical bone retention surface. Internal part of IDCAM Cam retention For a better connection accuracy. 2,5° Morse taper Internal Universal ISO threading RADIOGRAPHIC EXAMINATION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL Implant placement in canvas shape Technique of implant placement...

Ouvrir le catalogue en page 7
IDCAM - 8

PRESENTATION The IDCAM ST implant line (type IM)benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress without being affected. The IDCAM ST implant draws special attention to itself due to its Switching Cone neck and to its cylindro-tapered body identical to a dental root. The angulation, the state and the depth of the threads are specially studied to optimize the primary stabilization in any bone density and favor the immediate loading. Switching Cone Condensing high threads Anti-unscrewing groove...

Ouvrir le catalogue en page 8
IDCAM - 9

MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANT TYPE IMPLANTS DIFFUSION INTERNATIONAL *On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS conical drills for the IDCAM implants : Color code* IDCST 1552 All the dimensions are in millimeters. Important considerations The 3,5mm diameter implants must be used only for lower and upper lateral incisors. The IDCAM implants are supplied with a closing and a healing cap. To improve aesthetic...

Ouvrir le catalogue en page 9
IDCAM - 10

PRESENTATION The IDCAM M implant line (type IM) benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress, without being affected. The IDCAM M implant differentiates from the IDCAM S because of its mini threads neck, which favor immediate loading. Switching Cone Condensing mini threads Condensing high threads IDCAM M Implant features - Cylindro-tapered-shaped - 2,5° morse taper - Titanium alloy Ti6Al4V ELI - SMA + Ti02 state of surface Anti-unscrewing groove - Cam retention - Switching Cone -...

Ouvrir le catalogue en page 10
IDCAM - 11

MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANT TYPE IMPLANTS DIFFUSION INTERNATIONAL *On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS conical drills for the IDCAM implants : Color code* IMPLANTS DIFFUSION INTERNATIONAL NB: The 8mm length of IDCAM implants (P/N IDCM 0842 and IDCM 0852) do not have any CSO APEX. 10 mm length 12 mm length 15 mm length Important considerations LENGTH 15 The 8mm IDCAM implants do not have any CSO Apex. IDCM...

Ouvrir le catalogue en page 11
IDCAM - 12

SURGICAL PROTOCOL EXAMPLE OF AN IDCAM IMPLANT (example with the implant placement for an IDCAM implant P/N: IDCM1242) Use the Pilot drill P/N 1220 of 2mm diameter & 12mm length. Drill at 650 rpm with ample cooling. Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 650 rpm. If drilling procedure with bone harvesting: 150 rpm. Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 650 rpm. If drilling procedure with bone harvesting: 150 rpm. (This step is to be performed for an implant placement at the mandibule only.) Screw the...

Ouvrir le catalogue en page 12

Tous les catalogues et fiches techniques (PDF) IDI

  1. Implant ID3

    4 Pages

  2. catalogue 2019-

    116 Pages

  3. TURBOdrill

    4 Pages

  4. ID Bio

    32 Pages

  5. ID’BOX2017

    4 Pages