Extraits du catalogue

AQVL/AQVH 85 to 140 Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual
Ouvrir le catalogue en page 1
High Performance Components High SEER Special inverter fan (option) pCO1 control and PGD user interface 3 pump option Energy saving in partial load True dual circuit evaporator Optimized heat transfer coefficient 800 mm, 6 poles, axial fans Blue fin coil as standard on HP models 360° accessible compressor box for maintenance
Ouvrir le catalogue en page 2
Oustanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic mixture it behaves like a homogeneous substance (reduced service problems in case of leakage or re-charge) with negligible temperature glide. Refrigerant with superior thermo-dynamical proprieties compared to R22 and R407C, it allows to have more efficiency or compact and lighter systems and larger operating limits (T ambient = -15 °C in heating mode). 2 independant refrigerant circuits with 2 scroll compressors for each circuit. Bi-flow electronic expansion devices on...
Ouvrir le catalogue en page 3
Specifications (continued) Compressors ➜ Evaporator antifreeze protection. Each unit is equipped with 4 hermetic scroll compressors arranged in tandem configuration per refrigerant circuit. ➜ Heat pump defrost control for automatic operation. The compressors are fitted with an electronic control device which ensures protection of compressors against : - overheating and overloading, ➜ Management of the electronic expansion valves by means of EXV controller allowing optimized functions : cooling, heating, start-up and defrost. - reversal rotation and phase loss. ➜ Management of external...
Ouvrir le catalogue en page 4
Control : ^ HP and LP transducers (two for each circuit). ^ Evaporator water inlet température sensor. ^ Evaporator water outlet temperature sensor (with an antifreeze function). ^ Suction temperature sensor for EXV control. ^ Ambient air temperature sensor. ^ Coil temperature sensors. ^ Heat recovery condenser temperature sensor (AQVR only). Conformity with standards The following applies to all the sizes and versions of AQVL/AQVH/AQVR units : 3 Machine Directive : 2006/42/EC 3 Low Voltage Directive : 2006/95/EC 3 Electromagnetic Compatibility Directive : 2004/108/EC 3 Pressure Equipment...
Ouvrir le catalogue en page 5
All hydro options are supplied fitted inside the unit.
Ouvrir le catalogue en page 6
SAFETY / CONTROL DEVICES Note: For reasons of readability, one circuit only is shown. The second circuit is identical.
Ouvrir le catalogue en page 7
Note: For reasons of readability, one circuit only is shown. The second circuit is identical.
Ouvrir le catalogue en page 8
SAFETY/CONTROL DEViCES safety/control Devices
Ouvrir le catalogue en page 9
SAFETY/CONTROL DEViCES
Ouvrir le catalogue en page 10
SAFETY/CONTROL DEViCES safety/control Devices
Ouvrir le catalogue en page 11
Leaving water temperature (°C) Notes : Operating limits are referred to full load (4 compressors running). Maximum %glycol (ethylenic or propilenic) : 40% Notes : Operating limits are referred to full load (4 compressors running). Maximum %glycol (ethylenic or propilenic) : 40%
Ouvrir le catalogue en page 12
Operating Limits (cont'd) AQVL/AQVH 85 to 140 - R410A - BLN/HSE/HT/ELN Version - Heating 20 18 Leaving water temperature (°C) Notes : Operating limits are referred to full load (4 compressors running). Maximum %glycol (ethylenic or propilenic) : 40%
Ouvrir le catalogue en page 13
Fouling factors - Evaporator
Ouvrir le catalogue en page 14
Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape. (*) Gross value.
Ouvrir le catalogue en page 15
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape. (*) Gross value.
Ouvrir le catalogue en page 16
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape. (*) Gross value.
Ouvrir le catalogue en page 17
COMPRESSOR Number Crankcase Heater EVAPORATOR Number Water flow Rate Water Pressure Drop Refer to evaporator water pressure drop curve Antifreeze Heater DESUPERHEATER Number Heat recovery Water flow rate Water Pressure Drop Refer to desuperheater water pressure drop Frontal Surface FANS Number Input Power Input Power Outlet Diameter WEIGHT Shipping Weight Operating Weight DIMENSIONS Length Width (transport only) ACOUSTIC DATA Sound Power Level Sound Pressure Level (1) Sound Power Level Sound Pressure Level *** (1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO...
Ouvrir le catalogue en page 18
Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape. (*) Gross value. (**) HSE version.
Ouvrir le catalogue en page 19
(1) Sound pressure calculated at 10 m. Sound pressure levels refer to ISO standard 3744 with parallepiped shape. (*) Gross value.
Ouvrir le catalogue en page 20
(*) Sound pressure at 10 m, data refer to ISO standard 3744 with parallepiped shape. (**) Sound data valid in max. air flow rate/max. fan RPM condition.
Ouvrir le catalogue en page 25
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 26
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 27
Performance Data - AQVL 85 to 140 - R410A - HT AQVL Sizes HT Version P P P P P P P P P P P P P P P P P P P P cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (*) Compressors only LWT : Leaving water temperature
Ouvrir le catalogue en page 28
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 29
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 30
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 31
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 32
Performance Data - AQVH 85 to 140 - R410A - HT - Cooling AQVH Sizes HT Version P P P P P P P P P P P P P P P P P P P P cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* cool abs* (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (*) Compressors only LWT : Leaving water temperature
Ouvrir le catalogue en page 33
(*) Compressors only LWT : Leaving water température
Ouvrir le catalogue en page 34
Evaporator Water Pressure Drop AQVL 100 85-95 Water flow rate (l/s) Water flow rate (l/s) Desuperheater Water Pressure Drop - AQVL/AQVH 100 125-140 Water flow rate (l/s)
Ouvrir le catalogue en page 35
Water Pump Curves AQVL - 1 or 2 pump available static pressure 225 Available static presssure (kPa) Water flow rate (l/s) AQVH - 1 or 2 pump available static pressure 225 200 Available static presssure (kPa) Water flow rate (l/s)
Ouvrir le catalogue en page 36Tous les catalogues et fiches techniques (PDF) Systemair HSK
-
SyScroll 20-35 Air
8 Pages
-
AQWL/AQWH/AQWR 1404 to 2406
48 Pages
-
VLS/VLH/VLR 524 to 1204 NEW
52 Pages
-
Kälte- und Klimasysteme
208 Pages
-
Fan Coil
16 Pages
-
Water Source Heat Pump
8 Pages
-
Heat Recovery Fresh Air Unit
8 Pages
-
Axial Heating Unit
8 Pages
-
High Pressure Fan Coil Units
8 Pages
-
Blueline
8 Pages
Catalogues archivés
-
Fan Coil - 2014
8 Pages
-
CEILING TYPE
4 Pages
-
POOLLINE AIR HANDLING UNIT
4 Pages
-
MEDILINE PACKAGE HYGIENE
8 Pages
-
hsk
72 Pages
-
hygienline
8 Pages
-
Flexine catalog
12 Pages
-
blueline catalog
8 Pages